When connecting ISONAS hardware devices to Pure Access™, the device (client) initiates the connection to the software. This setting is “Client Mode” for reader-controller devices (see figure 3 below).
Since the device initiates the connection out to Pure Access, minimal firewall configuration is needed. If your firewall is blocking outbound ports or ephemeral ports, then rules may need to be added to the firewall to ensure a connection can be made.
ISONAS RC-03 and RC-04 reader-controller devices will initiate a connection on port 55533 and Pure Access will use an ephemeral port to complete the connection.
PowerNet™ IP-Bridge devices will initiate a connection on port 55533 and Pure Access will use ports 10001-10003 to complete the connection. IP-Bridges come in either two or three-door units.
- For a two-door unit, ports 10001 and 10002 will be used.
- For a three-door unit, the same ports are used in addition to 10003.