1. Navigate to the Access Points page
  2. Select next to the Access Point for which you need to configure the ASM, then choose Edit Device Settings
  3. Toggle the ASM slider to the on position
    1. Note: When using an ASM, the Fail Mode must be set to “Fail Secure”
  4. Select to proceed
  5. Select the desired lock state (once testing is complete) then click either or
    • It should be noted that once the latch test is completed, the access point will remain in the state that was selected; either Lock or Unlocked. This can result in openings being unintentionally left unsecured.
  6. Follow the prompts to configure the ASM
    1. First, factory reset the ASM by using a pin to hold the reset button down until the status light flashes green 3 times.
    2. Once the ASM has been reset, click
    3. An admit will be sent as a test:
      1. The reader’s LED should turn green for the duration of the latch interval
      2. The ASM’s status light should turn green for the duration of the latch interval
      3. The physical lock should unlatch for the duration of the latch interval
    4. If the admit test did not successfully unlatch the lock, click then follow the prompts to repeat the configuration process
  7. Proceed through the tests (or click ), then select when finished
  8. Once you have successfully paired the ASM module with the Reader Controller, send a Schedule command to the corresponding access point to set it back to Schedule.
Last modified: 10 April 2026

Was this helpful?

Yes No
You indicated this topic was not helpful to you ...
Could you please leave a comment telling us why? Thank you!
Thanks for your feedback.